宜昌市共联路(东站路-花溪路)及东站路(柏临河路-同强路)市政工程测 点1水 平 角 β ° ′ ″2改正数″3改正后水平角β ° ′ ″5方 位 角 α ° ′ ″6边 长Sm7坐 标 增 量⊿Xm8⊿Ym9改正数f⊿X′m10f⊿Y′m11改正后坐标增量⊿Xm12⊿Ym13X(N)m14坐 B14 33 05 40B13120 11 07.5-1.56120 11 05.94333 16 45.94B12-1178 58 45.25-1.56178 58 43.69332 15 29.63B12257 25 04.5-1.56257 25 02.9449 40 32.57B1131 08 30.5-1.56131 08 28.940 49 01.51B3303 34 58.25-1.56303 34 56.69124 23 58.2B6224.3443.225371.655237.292200.388-100.875-0.0062-0.013392.278-206.316-0.0122-0.025240.503283.348-0.0102-0.021237.2683.384-0.0065-0.013200.382392.266240.493237.261-100.888-206.341283.3273.3713391223.83733914.93391690.3713392082.6373392323.1303392560.3913392182.623∑精度评定991 18 267.91 18 18.291 18 18.21276.521070.44-20.4590.0350.0721070.402-20.531∑β=991°18′26″,方位角闭合差:fβ=∑β-(124°23′58.2″-33°05′40″+5×180°)=0°0′7.8″, fβ容=±10√5=±22.4″, fβ≤fβ容, 测角满足测量规范要求; 实测坐标增量:∑△X测=1070.437,∑△Y测=-20.459, 设计坐标增量: ∑△X设=1070.402,∑△Y设=-20.531;坐标增量闭合差: fX=∑△X测-∑△X设=218.006-218.069=0.035, fy=∑△Y测-∑△Y设=1103.233-1103.248=0.072, fd=±√(fx2+fy2)=0.08,∑D=1276.518,导线相对闭合差:K=fd/∑D=0.08/1276.518=1/15956<1/15000,工程测量规范规定: 一级导线全长相对闭合差K≤1/15000,本段导线测量精度达到一级导线测量规范要求。 测量: 计算: 复核: 日期:
附 合 导 线 平 差 计 算 表
宜昌市共联路(东站路-花溪路)及东站路(柏临河路-同强路)市政工程改正边 长水 平 角 β改正后水平角β方 位 角 α数S坐 标 增 量坐标增量改正数改正后坐标增量坐 水 平 角 β1 ° ′ ″2改正数″3改正后水平角β ° ′ ″5方 位 角 α ° ′ ″6边 长Sm7⊿Xm8⊿Ym9f⊿X′m10.000f⊿Y′m11⊿Xm12⊿Ym13X(N)m14B3124 23 53.16B6B5JM1JM3-1JM4B9B8117 56 36.241147.91-415.07685.573-0.045-0.058-415.025685.631269 47 01.750.91269 47 02.66214 10 55.8299.049-81.939-55.8169 56 .750.92169 56 55.67204 07 51.49203.971-186.15-83.38877 32 58.51 59 19200 19 020.9177 32 59.41101 40 50.9380.355-77.006372.4780.921 59 19.9286 40 10.82187.69510.9030.91200 19 02.91106 59 13.73276.842-80.8812.763315 21 14.750.92315 21 15.67242 20 29.40.0110.014-80.8702.777187.3680.0070.00910.910187.3770.0150.019-76.991372.4970.0080.010-186.139-83.3780.0040.005-81.935-55.33392560.3913392182.6233392100.6883391914.93391837.5583391848.4683391767.5983391708.058∑1197 56 30.75-5.491197 56 36.24精度评定∑β=1197°56′30.75″,方位角闭合差:fβ=∑β-(242°20′29.4″-124°23′53.16″+6×180°)=-0°0′5.49″, fβ容=±10√6=±24.5″, fβ≤fβ容, 测角满足测量规范要求; 实测坐标增量:∑△X测=-415.07,∑△Y测=685.573, 设计坐标增量: ∑△X设=-415.025,∑△Y设=685.631;坐标增量闭合差: fX=∑△X测-∑△X设=-415.073-(-415.025)=-0.045, fy=∑△Y测-∑△Y设=685.571-685.631=-0.058, fd=±√(fx2+fy2)=0.073,∑D=1147.916,导线相对闭合差:K=fd/∑D=0.073/1147.916=1/15725<1/15000,工程测量规范规定: 一级导线全长相对闭合差K≤1/15000,本段导线测量精度达到一级导线测量规范要求。 测量: 计算: 复核: 日期:
坐 标Y(E)m15535250.6715324.137535323.249535116.9085300.2355303.606535955.361 fβ≤fβ容, 测角满标增量闭合差: fX=∑导线相对闭合差:线测量规范要求。坐 标Y(E)m155303.606535955.3615359.718535816.340536188.838536376.2155360.992536527.385=±24.5″, fβ≤fβ.631;坐标增量闭合,∑D=1147.916,导线精度达到一级导线测量
因篇幅问题不能全部显示,请点此查看更多更全内容
Copyright © 2019- fupindai.com 版权所有 赣ICP备2024042792号-2
违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com
本站由北京市万商天勤律师事务所王兴未律师提供法律服务